{"id":"69d87acb-4b38-434a-98b7-21b4195fd1ae","name":"DSE6020 MKII Genset Controller","name_ar":"وحدة تحكم مولد DSE6020 MKII","slug":"dse6020-mkii-genset-controller","model":"DSE6020 MKII","part_number":"6020 MKII","brand_id":"5e3970ab-e7d4-40f6-8666-914cbf75cac7","category_id":"9c4c1ffc-3413-4a18-8811-523acff31fb1","subcategory_id":null,"short_description":"AMF genset controller with full 3-phase generator and mains sensing, VDO/Datcon/PT100 sensor curve support, and CAN/J1939 or MPU engine compatibility.","short_description_ar":"وحدة تحكم AMF بمراقبة كاملة ثلاثية الأوجه للمولد والشبكة العمومية، ودعم منحنيات حساسات VDO/Datcon/PT100، وتوافق مع CAN/J1939 أو المستشعر المغناطيسي (MPU).","full_description":"The DSE6020 MKII is an auto mains (utility) failure (AMF) control module from Deep Sea Electronics, suitable for single diesel, gas, or petrol genset applications requiring 3-phase generator and mains monitoring. The module measures and protects both the generator and the mains supply, automatically transfers the load between them based on mains availability, and offers manual breaker control via front-fascia buttons. The module is compatible with both electronic (CAN/J1939) and non-electronic (magnetic pick-up or alternator sensing) engines, and its analogue sensor inputs support named VDO, Datcon, and PT100 sensor curves alongside user-defined curves for oil pressure, coolant temperature, and fuel level. Configuration is via the DSE Configuration Suite PC software (over USB) or the front panel editor. The module stores the most recent 50 events in its configurable event log, and includes a large back-lit icon LCD display, generator and load power monitoring (kW, kVA, kVAr, pf), and an IP65-rated front panel (with the optional gasket).","full_description_ar":"وحدة التحكم DSE6020 MKII هي وحدة تحكم بميزة الفشل التلقائي للتيار الرئيسي (AMF) من شركة Deep Sea Electronics، مناسبة لتطبيقات مجموعات التوليد الفردية العاملة بالديزل أو الغاز أو البنزين والتي تتطلب مراقبة ثلاثية الأوجه للمولد والشبكة العمومية. تقيس الوحدة وتحمي كلًا من المولد وإمداد الشبكة العمومية، وتنقل الحمل تلقائيًا بينهما بناءً على توفر الشبكة العمومية، وتوفر تحكمًا يدويًا بالقاطع عبر أزرار اللوحة الأمامية. تتوافق الوحدة مع المحركات الإلكترونية (CAN/J1939) وغير الإلكترونية (مستشعر مغناطيسي أو حساس المولد)، وتدعم مداخل الحساسات التناظرية منحنيات حساسات VDO وDatcon وPT100 المسماة بالإضافة إلى المنحنيات المعرّفة من قبل المستخدم لضغط الزيت ودرجة حرارة التبريد ومستوى الوقود. يتم الإعداد عبر برنامج DSE Configuration Suite للكمبيوتر (عبر USB) أو محرر اللوحة الأمامية. تخزن الوحدة أحدث 50 حدثًا في سجل الأحداث القابل للتهيئة، وتشمل شاشة LCD كبيرة بأيقونات مضاءة من الخلف، ومراقبة قدرة المولد والحمل (kW, kVA, kVAr، معامل القدرة)، ولوحة أمامية بتصنيف IP65 (مع الحشية الاختيارية).","key_features":["Full 3-Phase Generator AND Mains (Utility) Voltage/Frequency Sensing","Automatic Load Transfer Between Mains and Generator","CAN/J1939 ECU Support Plus MPU/Alternator Speed Sensing","Named VDO, Datcon, and PT100 Sensor Curves Plus User-Defined Curves","Support for 0-10V & 4-20mA Oil Pressure Senders","Large Back-Lit Icon LCD Display (Heated Display Option Available)","USB Configuration Port (DSE Configuration Suite PC Software)","50-Event Configurable Event Log","Breaker Control Buttons on Front Fascia","Generator & Load Power Monitoring (kW, kVA, kVAr, pf) with Accumulated Energy","3 Engine Maintenance Alarms Plus Engine Run-Time Scheduler","IP65-Rated Front Panel (with Optional Gasket)"],"key_features_ar":["مراقبة كاملة ثلاثية الأوجه للجهد والتردد لكل من المولد والشبكة العمومية","نقل حمل تلقائي بين الشبكة العمومية والمولد","دعم وحدة تحكم إلكترونية CAN/J1939 بالإضافة إلى استشعار السرعة بالمستشعر المغناطيسي/المولد","منحنيات حساسات مسماة VDO وDatcon وPT100 بالإضافة إلى منحنيات معرّفة من قبل المستخدم","دعم مستشعرات ضغط الزيت من نوع 0-10 فولت و4-20 مللي أمبير","شاشة LCD كبيرة بأيقونات مضاءة من الخلف (خيار شاشة مسخنة متاح)","منفذ USB للإعداد (برنامج DSE Configuration Suite)","سجل أحداث قابل للتهيئة بسعة 50 حدثًا","أزرار تحكم بالقاطع على اللوحة الأمامية","مراقبة قدرة المولد والحمل (kW, kVA, kVAr، معامل القدرة) مع الطاقة التراكمية","3 إنذارات صيانة للمحرك بالإضافة إلى جدولة زمن تشغيل المحرك","لوحة أمامية بتصنيف IP65 (مع الحشية الاختيارية)"],"specifications":[],"applications":["Single Diesel Generator Sets Requiring Mains Sensing","Single Gas or Petrol Generator Sets Requiring Mains Sensing","Automatic Mains Failure (AMF) Standby Power Systems","Installations Using VDO, Datcon, or PT100 Branded Sensors","Generator Control Panels & ATS Panels Requiring 3-Phase Metering"],"applications_ar":["مجموعات التوليد الفردية بالديزل التي تتطلب مراقبة الشبكة العمومية","مجموعات التوليد الفردية بالغاز أو البنزين التي تتطلب مراقبة الشبكة العمومية","أنظمة الطاقة الاحتياطية بميزة الفشل التلقائي للتيار الرئيسي (AMF)","التركيبات التي تستخدم حساسات من ماركات VDO أو Datcon أو PT100","لوحات التحكم بالمولدات ولوحات ATS التي تتطلب قياسًا ثلاثي الأوجه"],"compatibility":["CAN/J1939 ECU-Equipped Diesel Engines","MPU/Magnetic Pickup or Alternator Speed Sensing Engines","VDO, Datcon, and PT100 Pressure/Temperature Sensors","3 Phase, 4 Wire Generator and Mains AC Systems"],"compatibility_ar":["محركات ديزل مزودة بوحدة تحكم إلكترونية CAN/J1939","محركات تعمل بمستشعر السرعة المغناطيسي (MPU) أو حساس المولد","حساسات ضغط ودرجة حرارة من ماركات VDO وDatcon وPT100","أنظمة كهرباء ثلاثية الأوجه رباعية الأسلاك للمولد والشبكة العمومية"],"images":["https://tghnlibrunhataeqsasl.supabase.co/storage/v1/object/public/product-assets/images/1788274585086-t15h5g.jpg","https://tghnlibrunhataeqsasl.supabase.co/storage/v1/object/public/product-assets/images/1788274585089-r8wnce.jpg","https://tghnlibrunhataeqsasl.supabase.co/storage/v1/object/public/product-assets/images/1788274585089-fc78pk.jpg","https://tghnlibrunhataeqsasl.supabase.co/storage/v1/object/public/product-assets/images/1788274585089-3neod9.jpg"],"datasheet_url":"https://pharaonicgenerators.com/docs/deep-sea/dse6010-mkii-dse6020-mkii-datasheet.pdf","related_products":[],"availability":"In Stock","seo_title":"DSE6020 MKII AMF Controller (Deep Sea)","seo_title_ar":"شاشة مولد DSE6020 MKII AMF","seo_description":"Deep Sea DSE6020 MKII AMF genset controller: 3-phase generator and mains sensing, VDO/Datcon/PT100 sensors, CAN/J1939 or MPU engines.","seo_description_ar":"وحدة تحكم مولد DSE6020 MKII بوظيفة AMF: مراقبة المولد والشبكة ثلاثية الأوجه، حساسات VDO/Datcon/PT100، وتدعم محركات الانجيكشن CAN/J1939 أو MPU.","featured":false,"sort_order":3,"created_at":"2026-08-20T08:15:08.259051+00:00","updated_at":"2026-11-07T12:55:06.902187+00:00","cutout_width_mm":180,"cutout_height_mm":100,"replacement_for":[],"ecu_compatibility":[],"sensor_support":{"vdo":true,"pt100":true,"datcon":true,"custom_curve":true},"commissioning_support":false,"application_control":["diesel_gas_genset"],"operation_mode":["amf","ats","auto_start","manual"],"ecu_protocol":["dual"],"programming_method":["pc_usb","manual_panel"],"comm_ports":[],"has_event_log":true,"event_log_capacity":"50 log entries","supported_languages":["english"],"overall_dimensions":"(W×H×D mm): 216 × 158 × 43 mm","dc_power_supply":"8.0 – 35.0 V DC","io_count":"6 Digital + 4 Analogue Sensor Inputs (+ E-Stop + MPU) | Outputs: 6 (Fuel + Crank + 4× Configurable DC)","live_display_flags":{"mains":{"mains_voltage":true,"mains_frequency":true,"mains_voltage_ll":true,"mains_voltage_ln":true},"power":{"amps":true,"volts":true,"power_kw":true,"freq_speed":true,"power_factor":true,"gen_frequency":true,"gen_voltage_ll":true,"gen_voltage_ln":true,"energy_counters":true,"gen_active_power":true,"gen_apparent_power":true,"gen_reactive_power":true},"engine":{"rpm":true,"run_hours":true,"fuel_level":true,"coolant_temp":true,"oil_pressure":true,"battery_voltage":true},"system":{"maintenance_notice":true,"controller_datetime":true}},"protection_flags":{"status":{"event_log_rtc":true,"j1939_dtc_display":true},"warning":{"low_fuel":true,"charger_failure":true,"ecu_warning_dtc":true,"maintenance_due":true,"battery_over_voltage":true,"battery_under_voltage":true,"battery_voltage_warning":true},"critical":{"rpm_lost":true,"over_power":true,"over_speed":true,"under_speed":true,"over_current":true,"over_voltage":true,"stop_failure":true,"under_voltage":true,"over_frequency":true,"under_frequency":true,"low_oil_pressure":true,"high_coolant_temp":true,"overspeed_underspeed":true,"over_under_voltage_freq":true,"emergency_stop_fail_start":true,"overcurrent_short_circuit":true}},"display_backlight_type":"Backlit Icon LCD Display","display_screen_width_mm":null,"display_screen_height_mm":null,"display_reading_style":["both"],"unique_features":[{"items":[{"title_ar":"منحنيات حساسات مسماة VDO وDatcon وPT100","title_en":"Named VDO, Datcon & PT100 Sensor Curves","description_ar":"تدعم مداخل ضغط الزيت ودرجة حرارة التبريد ومستوى الوقود التناظرية منحنيات معدة مسبقًا لحساسات VDO وDatcon وPT100، قابلة للاختيار مباشرة من قائمة الحساسات دون الحاجة لمعايرة يدوية.","description_en":"Oil pressure, coolant temperature, and fuel-level analogue inputs support pre-loaded curves for VDO, Datcon, and PT100 sensors, selectable directly from the sensor list without manual calibration."},{"title_ar":"مستشعرات ضغط زيت 0-10 فولت و4-20 مللي أمبير","title_en":"0-10V & 4-20mA Oil Pressure Senders","description_ar":"يدعم المدخل التناظري D مستشعرات ضغط الزيت من نوع الجهد (0-10 فولت) والتيار (4-20 مللي أمبير) بالإضافة إلى المستشعرات المقاومة القياسية.","description_en":"Analogue Input D supports voltage-type (0-10V) and current-type (4-20mA) oil pressure senders in addition to standard resistive senders."},{"title_ar":"منحنيات حساسات معرّفة من قبل المستخدم","title_en":"User-Defined Sensor Curves","description_ar":"عندما لا يتطابق الحساس المركب مع منحنى ماركة معد مسبقًا، يمكن تعريف منحنى مقاومة/حرارة أو مقاومة/ضغط مخصص عبر برنامج DSE Configuration Suite.","description_en":"When the installed sensor does not match a pre-loaded brand curve, a custom resistance/temperature or resistance/pressure curve can be defined via the DSE Configuration Suite."}],"title_ar":"دعم حساسات مرن","title_en":"Flexible Sensor Support"},{"items":[{"title_ar":"منفذ إعداد USB","title_en":"USB Configuration Port","description_ar":"يوفر منفذ USB مخصص اتصالًا ببرنامج DSE Configuration Suite للكمبيوتر لإعداد كامل للمعاملات والتسلسلات والمؤقتات والإنذارات.","description_en":"A dedicated USB port connects to the DSE Configuration Suite PC software for full parameter, sequence, timer, and alarm configuration."},{"title_ar":"خيار الشاشة المسخنة","title_en":"Heated Display Option","description_ar":"يضيف الطراز 6020-04 شاشة مسخنة، مما يوسع نطاق التشغيل المقنن حتى -40° مئوية لتركيبات الطقس البارد القاسي.","description_en":"The 6020-04 variant adds a heated display, extending the rated operating range down to -40°C for extreme cold-weather installations."}],"title_ar":"الاتصال والإعداد","title_en":"Communication & Configuration"},{"items":[{"title_ar":"لوحة أمامية بتصنيف IP65 (حشية اختيارية)","title_en":"IP65-Rated Front Panel (Optional Gasket)","description_ar":"تصل إلى تصنيف الحماية IP65 من الجانب الأمامي للوحدة عند التركيب في لوحة التحكم مع تركيب الحشية الاختيارية.","description_en":"Achieves IP65 protection from the front of the module when installed into a control panel with the optional gasket fitted."},{"title_ar":"نطاق درجة حرارة تشغيل واسع (-30° إلى +70° مئوية)","title_en":"Wide Operating Temperature Range (-30°C to +70°C)","description_ar":"مصنفة للتشغيل المستمر من -30° إلى +70° مئوية (الشاشة القياسية)، مع تخزين حتى -40° مئوية، مناسبة لتركيبات المجموعات الخارجية القاسية.","description_en":"Rated for continuous operation from -30°C to +70°C (standard display), with storage down to -40°C, suitable for demanding outdoor genset installations."},{"title_ar":"حماية تحميل زائد للمولد (كيلوواط)","title_en":"Generator Overload Protection (kW)","description_ar":"تراقب قدرة المولد الفعلية بالكيلوواط وتفصل عند تجاوز حد تحميل زائد قابل للتهيئة لحماية المولد من التحميل الزائد المستمر.","description_en":"Monitors true generator kW output and trips on a configurable overload threshold to protect the alternator from sustained overload."}],"title_ar":"التصنيف والمتانة","title_en":"Rating & Durability"}],"paralleling_capability":[],"manual_url":"https://pharaonicgenerators.com/docs/deep-sea/dse6010-mkii-dse6020-mkii-operator-manual.pdf","compatible_brands":[],"compatible_brands_indirect":[],"brand":{"id":"5e3970ab-e7d4-40f6-8666-914cbf75cac7","name":"Deep Sea Electronics (DSE)","name_ar":null,"slug":"deep-sea","description":null,"description_ar":null,"logo_url":"/assets/storage/images/1787498304557-sygsv5.webp","website_url":null,"sort_order":2,"created_at":"2026-08-19T11:30:20.964924+00:00","updated_at":"2026-09-03T22:30:37.194225+00:00","brand_type":"component_maker"},"category":{"id":"9c4c1ffc-3413-4a18-8811-523acff31fb1","name":"Controllers","name_ar":"وحدات التحكم","slug":"generator-controllers","description":"Digital and analog control modules for generator operation, monitoring and automation.","description_ar":null,"image_url":null,"icon":"Cpu","sort_order":1,"created_at":"2026-08-05T12:50:30.389222+00:00","updated_at":"2026-09-24T11:46:33.911557+00:00","is_hidden":false},"subcategory":null,"related_slugs":["water-temperature-sensor16m","vdo-oil-pressure-sensor-0-10-bars-18","control-switches-breakers-relays-relays-24v-11-pin","selector-switch-onoff","ignition-starter-switch","emergency-stop-push-button"],"card_brand":{"mode":"compat","slugs":["deep-sea"]},"card_brands":[{"id":"5e3970ab-e7d4-40f6-8666-914cbf75cac7","name":"Deep Sea Electronics (DSE)","name_ar":null,"slug":"deep-sea","description":null,"description_ar":null,"logo_url":"/assets/storage/images/1787498304557-sygsv5.webp","website_url":null,"sort_order":2,"created_at":"2026-08-19T11:30:20.964924+00:00","updated_at":"2026-09-03T22:30:37.194225+00:00","brand_type":"component_maker"}]}